Repository navigation
Channel energy scan - #149
Conversation
|
The energy scanning API is expected to return a number between 0 and 255, with 0 being "low" and 255 being "high". This is to make values comparable across radios, since all others return a number 0-255. In bellows, I implemented it like so: https://github.com/zigpy/bellows/blob/58f8a8079a6fa1d25fe536e5d9e3fcfcbf41389c/bellows/zigbee/util.py#L105-L132. |
|
Thanks! Will update the code. |
|
Fixed. |
|
Rebased and added tests |
Codecov ReportAll modified lines are covered by tests ✅
Additional details and impacted files@@ Coverage Diff @@
## dev #149 +/- ##
==========================================
+ Coverage 98.86% 99.13% +0.26%
==========================================
Files 6 6
Lines 793 807 +14
==========================================
+ Hits 784 800 +16
+ Misses 9 7 -2
☔ View full report in Codecov by Sentry. |
Add support for per-channel energy detect for XBee coordinators.
Logs:
Prtially implements #112 though it is not a stand-alone tool.