Autonomous filtration pump controller for APA Devices pool automation
·
·
- PCF8574AT I2C relay expander (default) or direct Arduino GPIO — one constructor covers both
- Non-blocking state machine: IDLE → STARTING → RUNNING → STOPPING
- Safe boot: all relays start OFF regardless of previous relay or pin state
- Manual override:
FORCE_ON,FORCE_OFF,AUTO— with optional timeout or midnight auto-return - Extension relay outputs on PCF P4–P7 for lights or extra equipment
- Schedule callback drives pump on/off without any external library
- Daily runtime target with catch-up logic and optional time window
- Midnight rollover via RTC epoch callback or 24-hour millis() fallback
- UVC sanitizer — ON before pump, OFF after (configurable pre/post delay)
- AUX device (heat pump, ozone, etc.) — ON after pump, OFF before pump stops
- Solar valve — opens when solar drives the pump; instantly closes in manual mode
- Absorber–pool temperature dead-band hysteresis (configurable start/stop deltas)
- Pool cooling: runs in reverse when pool temperature exceeds maximum
- Day/night boundary gate via RTC epoch callback
- Solar safety (Priority 0): absorber too hot → pump ON + valve OPEN, overrides even
FORCE_OFF
- Overcurrent — learns the pump's own normal current, alarms at × 1.5; no pump rating to enter; silent with an external contactor (details)
- Dry-run — pressure below EMA baseline × 40% (or absolute minimum before EMA builds)
- Overpressure — absolute hard limit at
maxPressure(the filter's rated pressure); optional sudden-rise alarm - Pressure monitoring can be switched off at runtime —
setPressureEnabled(false)for installations without a pressure sensor (details) - Learned baselines never learn a fault — no learning while an alarm is active, nor from a dry pipe or a motor-less current sensor
- Freeze protection — pool temp below 4.5 °C → cyclic run (5 min ON / 10 min rest); suppressed if dry-run detected
- No-flow stub — flow switch confirmed after settle; hardware-ready for future sensor
- All alarms are latching — explicit
acknowledgeAlarm()required
- Filter status — clean / filling / backwash needed, from the pressure rise above the clean-filter pressure (details)
- Clean pressure learned automatically on the first run; one call after each backwash re-learns it
- 564 B SRAM on Arduino Uno with all features registered — fits comfortably in 2 KB
- 23 boolean flags packed into 3 bytes; all string literals in flash (
F()macro) - EEPROM: 12 bytes, magic + version + checksum validation, persists target and clean pressure
- Zero
delay()calls — every path returns within oneloop()iteration - Designed to integrate with APADOSE and APALCDGUI via callback bridges — no coupling
Arduino IDE: Sketch → Include Library → Add .ZIP Library → select the APAPUMP folder.
PlatformIO:
lib_deps =
https://github.com/apadevices/APAPUMPAPAPUMP controls a pool filtration pump and up to three follower devices (UVC lamp, AUX device, solar valve) through a PCF8574AT I2C relay expander or direct Arduino output pins. Each call to update() in your loop() advances the state machine, checks every safety guard in priority order, and fires alarm callbacks when something is wrong — all without blocking.
Out of the box, the zero-arg constructor targets the APA Devices HMI board v1.0: PCF8574AT at 0x3C with pump on P0, UVC on P1, AUX on P2, and solar valve on P3. Every optional feature is disabled by default and activated with one method call.
┌──────────────────────────────────┐
│ pump.begin() │
▼ │
[ IDLE ] │
│ │
_shouldPumpRun() = true │
min OFF time OK (60 s) │
│ │
[ STARTING ] │
│ │
UVC pre-delay (default 5 s) │
│ │
[ RUNNING ] ◄── safety alarms checked: │
│ current · pressure · │
│ flow · freeze │
_shouldPumpRun() = false │
min run time OK (300 s) │
│ │
[ STOPPING ] │
│ │
AUX lead ──► pump OFF ──► UVC post-delay ────────────────┘
Guards that bypass min-run time: FORCE_ON and FORCE_OFF — manual mode suspends timing guards.
Time → 0 5s 15s [pump runs…] Ts-30s Ts Ts+30s
│ │ │ │ │ │ │
UVC: ├──ON──────┼──────────┼────────────────┼────────┼─────────┼──OFF───┤
Pump: ON──────────────────────────────────OFF
AUX: ON───────────────OFF
◄─ pre ──►◄──────────────── RUNNING ──────────►◄─ lead ─►◄─ post─►
Ts = moment the stop sequence begins. pre = enableUVC(preDelayS, …). lead = enableAux(…, stopLeadS). post = enableUVC(…, postDelayS).
Every update() tick calls the priority engine. The first rule that matches wins:
| Priority | Condition | Result |
|---|---|---|
| P0 | Solar absorber > safety temp (default 50 °C) | Pump ON + valve OPEN — overrides FORCE_OFF |
| P1 | FORCE_OFF manual mode |
Pump OFF |
| P2 | FORCE_ON manual mode |
Pump ON |
| P3 | External request callback returns true |
Pump ON |
| P4 | Freeze: pool temp < threshold AND water present | Pump ON |
| P5a | Solar: absorber > pool + startDelta | Pump ON (hysteresis) |
| P5b | Catch-up: daily runtime < daily target (window OK) | Pump ON |
| P5c | Schedule callback returns true |
Pump ON |
| — | None of the above | Pump OFF |
PCF8574AT at I2C address 0x3C
│
├─ P0 ── Pump relay (always required)
├─ P1 ── UVC relay (optional — enableUVC())
├─ P2 ── AUX relay (optional — enableAux())
└─ P3 ── Solar valve relay (optional — enableSolar(…, useValve=true))
│
├─ P4 ── Extension relay (optional — setExtraOutput(4, on/off))
├─ P5 ── Extension relay (optional — setExtraOutput(5, on/off))
├─ P6 ── Extension relay (optional — setExtraOutput(6, on/off))
└─ P7 ── Extension relay (optional — setExtraOutput(7, on/off))
PCF HIGH = relay ON, LOW = relay OFF. begin() writes 0x00 immediately — all relays start OFF.
#include <Wire.h>
#include <APAPUMP.h>
ApaPump pump; // PCF at 0x3C — pump=P0, uvc=P1, aux=P2, valve=P3
void setup() {
Wire.begin(); // required for PCF mode — call before pump.begin()
pump.begin(); // all relays OFF, EEPROM loaded
}
void loop() {
pump.update(); // non-blocking — call every loop()
}// Active-high relay (most modules)
ApaPump pump(RELAY_DIRECT, 7); // pump on pin 7
// Active-low relay (some modules)
ApaPump pump(RELAY_DIRECT, 7);
pump.setActiveLow(); // call BEFORE pump.begin()
// Multiple relays, direct GPIO
ApaPump pump(RELAY_DIRECT, 7, 8, 9, 10); // pump=7, uvc=8, aux=9, valve=10#include <Wire.h>
#include <APAPUMP.h>
ApaPump pump;
bool scheduleActive() {
// return true when your RTC time falls inside a timer slot
return false; // replace with real logic
}
void onAlarm(PumpAlarm alarm) {
if (alarm == PUMP_ALARM_NONE) return; // alarm was cleared
Serial.print(F("Pump alarm: "));
switch (alarm) {
case PUMP_ALARM_OVERCURRENT: Serial.println(F("overcurrent")); break;
case PUMP_ALARM_LOW_PRESSURE: Serial.println(F("dry run")); break;
case PUMP_ALARM_HIGH_PRESSURE: Serial.println(F("high pressure")); break;
case PUMP_ALARM_NO_FLOW: Serial.println(F("no flow")); break;
default: break;
}
// pump continues running — call pump.acknowledgeAlarm() when investigated
}
void setup() {
Wire.begin();
pump.begin(scheduleActive); // schedule drives on/off
pump.enableUVC(5, 30); // UVC: 5 s pre, 30 s post
pump.enableAux(10, 30); // AUX: 10 s delay, 30 s lead
pump.setPumpAlarmCallback(onAlarm);
}
void loop() { pump.update(); }Force the pump on or off at any time. All timing guards and schedules are suspended:
pump.setManualMode(FORCE_ON); // force pump ON (e.g. vacuuming, winterising)
pump.setManualMode(FORCE_OFF); // force pump OFF (e.g. plumbing, service)
pump.setManualMode(AUTO); // return to automatic controlThe solar valve closes immediately when entering FORCE_ON — operator gets full system pressure.
Auto-return options — pick one or both:
// Timeout: returns to AUTO after 60 minutes
ApaPump pump(RELAY_PCF, 0x3C, 0, 1, 2, 3, 60); // 6th constructor parameter
pump.setManualTimeout(60); // or set at any time
// Midnight reset (requires setMidnightCallback())
pump.setManualAutoReset(true);Note: Solar safety (P0) still applies even in FORCE_OFF. If the absorber reaches the safety temperature, the pump runs to prevent heat damage regardless of manual mode.
Each follower is independent and optional. Wire the relay to the corresponding PCF bit (or GPIO pin), then call the enable method:
// UVC lamp: ON 5 s before pump, OFF 30 s after pump stops
pump.enableUVC(5, 30);
// AUX device (heat pump, ozone): ON 10 s after pump starts, OFF 30 s before pump stops
pump.enableAux(10, 30);
// Solar valve: open when solar logic drives the pump
// useValve=true enables the valve relay on P3 (or direct pin d)
pump.enableSolar(absorberTempCb, poolTempCb, /*useValve=*/true, ...);UVC pre-delay — when a pre-delay is configured, the pump enters STARTING state while UVC warms up. If the reason to start disappears during STARTING (e.g. schedule ends), the sequence is cancelled cleanly — UVC turns off and the pump never fires.
Solar logic becomes the sole on/off driver when enabled — the schedule callback is only used for the daily runtime target.
pump.enableSolar(
[]() { return adc.getSolarTemp(); }, // absorber temperature callback
[]() { return adc.getPoolTemp(); }, // pool temperature callback (optional)
true, // useValve — open valve when solar running
8.0f, // startDelta: start when absorber > pool + 8°C
3.0f, // stopDelta: stop when absorber < pool + 3°C
32.0f, // maxPoolTemp: pool cooling if pool > 32°C
2.0f, // coolDelta: cool when absorber < pool - 2°C
50.0f // safetyTemp: force pump ON if absorber > 50°C
);
// Optional: restrict solar heating to daytime hours
pump.setSolarDayNight(
[]() { return rtc.getEpoch(); }, // Unix epoch callback
7, // daytime starts at 07:00
20 // daytime ends at 20:00
);Absorber temp
│
│ START threshold = pool + startDelta
─────┼──────────────────────────────────────────────────────
│ ← pump ON pump ON →
│
─────┼──────────────────────────────────────────────────────
│ STOP threshold = pool + stopDelta
│
The gap between start and stop thresholds prevents rapid on/off cycling when temperature hovers near the boundary. Increase startDelta − stopDelta for wider hysteresis.
// Option A: fixed target (user sets it once)
pump.setDailyTarget(360); // run 6 hours per day
// Option B: use the APALCDGUI timer sum as the target
pump.begin(scheduleActive, nullptr,
[]() { return gui.getTimerTotalMinutes(); });
// Query progress
uint16_t ran = pump.getDailyRuntimeMinutes();
bool met = pump.isDailyTargetMet();When solar is enabled and the daily target is not met, catch-up runs until the target is reached:
// Optional: limit catch-up to daytime hours (requires setMidnightCallback)
pump.setCatchupWindow(8, 20); // catch-up only between 08:00 and 20:00All alarms are latching — the pump does not stop automatically (your sketch decides the action). Call acknowledgeAlarm() after investigation to clear.
| Alarm | Triggers when | Requires |
|---|---|---|
PUMP_ALARM_OVERCURRENT |
current > learned baseline × 1.5 (details) | setCurrentCallback() |
PUMP_ALARM_LOW_PRESSURE |
pressure below 40% of EMA baseline (dry-run) | enablePressure() |
PUMP_ALARM_HIGH_PRESSURE |
pressure > maxPressure (absolute) |
enablePressure() with maxPressure > 0 |
PUMP_ALARM_HIGH_PRESSURE |
sudden rise > baseline × (1 + peakPct %) | setPressurePeakAlarm() (off by default) |
PUMP_ALARM_NO_FLOW |
flow switch reports no flow after 30 s settle | setFlowCallback() |
Alarm checks run every update() once the pump has run 30 s; overcurrent is checked with each 10 s current sample. While an alarm is active, nothing is learned — a dry run or an overcurrent never becomes the new "normal".
The sudden-rise alarm does not detect a dirty filter. Its baseline follows slow changes within minutes, so weeks of clogging never trip it — that is what filter status is for. It catches fast changes such as a valve closed while the pump runs. Turning a multiport valve (e.g. to backwash) while the pump runs can trip it, which is why it is off by default.
A pump that keeps running dry or overloaded can be destroyed within minutes, so most sketches should stop it. Keep it stopped while the alarm is active — setManualMode(FORCE_OFF) alone returns to AUTO after the manual timeout and would restart the pump, and the library skips its checks while an alarm is active:
void loop() {
pump.update();
if (pump.getAlarm() != PUMP_ALARM_NONE && pump.getManualMode() != FORCE_OFF)
pump.setManualMode(FORCE_OFF); // re-asserted until the operator acknowledges
}
// Operator has checked the pump (HMI button, Serial command, ...):
pump.acknowledgeAlarm();
pump.setManualMode(AUTO);Alarm callback pattern:
pump.setPumpAlarmCallback([](PumpAlarm alarm) {
if (alarm == PUMP_ALARM_NONE) {
// alarm was acknowledged — update LCD, clear indicator
gui.cancelActiveAlert();
return;
}
// alarm fired — notify operator
gui.postActiveAlert(F("Pump alarm!"), F("Check equipment"),
ALERT_CRITICAL, []() { pump.acknowledgeAlarm(); });
});The alarm callback is the right place to drive any physical indicator — buzzer, LED, relay. No extra library method needed.
Direct GPIO (no APASENSE):
pump.setPumpAlarmCallback([](PumpAlarm alarm) {
bool active = (alarm != PUMP_ALARM_NONE);
digitalWrite(5, active ? HIGH : LOW); // buzzer on pin 5
});With APASENSE (v1.1.0+, recommended for APA hardware):
pump.setPumpAlarmCallback([](PumpAlarm alarm) {
bool active = (alarm != PUMP_ALARM_NONE);
adc.setLed(0, active); // LED0 = PCF P4
if (active) adc.alert(BUZZER_ALARM, true); // repeating alarm pattern
else adc.stopAlert(); // silence when alarm clears
});Tip: APASENSE owns the PCF expander LEDs and buzzer.
alert(BUZZER_ALARM, true)plays a repeating triple-beep untilstopAlert()is called — no delay() or manual timer needed.
When enablePressure() is registered, APAPUMP builds a dual pressure baseline (EMA): one for normal running, one for when the solar valve is open (higher pressure expected due to absorber resistance). One sample is taken every 10 s once the pump has run 30 s; after 5 samples the baseline is ready and PUMP_ALARM_LOW_PRESSURE fires when pressure drops below 40 % of it.
Before the baseline is ready, an absolute minimum of 0.1 bar (APAPUMP_PRESSURE_ABS_MIN) is used. Readings below 0.1 bar are never learned — a pump running dry cannot teach itself that "no pressure" is normal.
Not every installation has a pressure sensor (small garden pools often don't). Register the sensor once with enablePressure(), then switch monitoring on or off at any time — e.g. from an installer menu, with the choice stored by your sketch:
pump.enablePressure([]() { return adc.getPressure(); }, 2.5f);
pump.setPressureEnabled(settings.pressureOn); // OFF: no pressure checks at allWith pressure off there is no dry-run, no high-pressure alarm and no filter status — the pump then has no protection against running dry. Without a sensor, leaving it on is harmless (a sensor that never delivers a valid reading keeps every pressure check inactive), but an explicit OFF also ignores a disconnected input that floats to a plausible value. Switching off clears the last reading and the learned baselines; switching on re-learns them (~80 s of running). The stored clean-filter pressure is kept.
A sand or cartridge filter clogs slowly, and the pressure in front of it rises. getFilterStatus() compares the running pressure with the pressure measured when the filter was clean:
| Status | Rise above the clean pressure | Example (clean = 1.0 bar) |
|---|---|---|
FILTER_CLEAN |
below 0.4 bar | below 1.4 bar |
FILTER_FILLING |
0.4 bar or more | 1.4 bar or more — backwash soon |
FILTER_BACKWASH_NEEDED |
0.8 bar or more | 1.8 bar or more — backwash now |
FILTER_UNKNOWN |
no clean pressure or no baseline yet | first ~80 s of running after each boot |
The clean pressure is learned for you. On the first run after installation (pump running, solar valve closed, at least 0.1 bar) the library takes its first stable pressure (~80 s of running) as the clean pressure and saves it to EEPROM. Every pool's pipework gives a different normal pressure — this way the limits follow your pool, not a fixed number.
After every backwash call learnCleanPressure() once (e.g. from an HMI button). It clears the stored value and learns the new clean pressure during the next ~80 s of running — if the pump is off, it simply waits for the next run. It never copies a single reading, so a spike or a stopped pump cannot be learned by mistake.
pump.enablePressure([]() { return adc.getPressure(); }, 2.5f);
switch (pump.getFilterStatus()) {
case FILTER_FILLING: /* show "backwash soon" */ break;
case FILTER_BACKWASH_NEEDED: /* show "backwash filter + LEARN" */ break;
default: break;
}
// after backwashing:
pump.learnCleanPressure();- It is a status, not an alarm — backwashing is maintenance, not an emergency. It keeps its value while the pump is stopped.
- The limits are household-pool values. Change them with
setFilterThresholds(warn, backwash)at runtime, orbuild_flags = -DAPAPUMP_FILTER_WARN_DELTA=0.5f -DAPAPUMP_FILTER_BACKWASH_DELTA=1.0f. setCleanPressure(bar)sets the clean pressure by hand;setCleanPressure(0)forgets it (the current baseline is then taken as clean).- Keep
maxPressureinenablePressure()above the backwash level and at or below the filter's rated maximum (often 2.5 bar for household sand filters — check the label).
setCurrentCallback() gives APAPUMP the pump's current in amps (APASENSE: adc.getCurrent()). A current well above normal means the motor is struggling: a blocked or jammed impeller, failing bearings, or a motor winding fault.
How it works
- Learns the pump's own normal current — no pump rating to enter. A 0.5 kW and a 1.5 kW pump each learn their own value.
- One sample every 10 s once the pump has run 30 s (motor start-up current is ignored).
- After 5 samples (~80 s of running) the baseline is ready and the alarm arms.
PUMP_ALARM_OVERCURRENTfires when a sample exceeds 1.5 × the baseline. Checked every 10 s, so a fault is caught within 10 s.- The baseline adapts slowly to normal changes (weight 5 % per sample) and is kept across pump cycles.
What it does not do
- It does not stop the pump by itself — see Stopping the pump on an alarm.
- It does not detect a dry run (a dry pump draws less current) — that is the pressure sensor's job.
- It is not a replacement for the motor's own thermal protection or the circuit breaker. It warns early; the breaker protects the wiring.
Direct drive vs. external contactor — check how your pump is wired:
| Wiring | What passes the current sensor | Overcurrent protection |
|---|---|---|
| Pump powered directly through the board's relay | the pump's current (typically 2–8 A) | active |
| Board relay only switches an external contactor in the electrical box | only the contactor's coil (well under 0.5 A) | silent — no alarms, no false alarms |
Safety: switching the pump through an external contactor (rated for motor loads) is always recommended over connecting it directly to a controller relay. Small board relays are often not rated for a motor's start-up current.
Readings below 0.5 A (APAPUMP_CURRENT_MIN_A) are ignored: they are not a motor, just sensor noise or a contactor coil. So with a contactor the feature switches itself off safely — nothing to configure. With a contactor, pressure monitoring (dry run, high pressure, filter status) is the pump's protection; use a motor protection switch in the electrical box for the motor itself.
Good to know
- The baseline lives in RAM: after each boot it is re-learned during the first ~80 s of running, with no overcurrent alarm during that time.
- Nothing is learned while an alarm is active, so an overload never raises its own threshold.
- After replacing or servicing the pump, call
resetCurrentBaseline()so the new motor's current is learned. - A very small pump (under ~0.5 A): lower the floor with
build_flags = -DAPAPUMP_CURRENT_MIN_A=0.3f.
pump.enableFreezeProtection(
[]() { return adc.getPoolTemp(); }, // pool/pipe temperature
4.5f // threshold in °C (default)
);When pool temperature drops below the threshold, the pump cycles to prevent pipes from freezing: runs for APAPUMP_FREEZE_ON_SEC (default 5 min), rests for APAPUMP_FREEZE_OFF_SEC (default 10 min), and repeats until temperature rises. Both durations are overridable via build_flags. Dry-run interlock: if the pressure sensor is enabled, calibrated, and indicates no water in the pipes (pressure near zero), freeze protection is suppressed — forcing the pump without water would burn the motor.
APAPUMP, APADOSE, and APALCDGUI are independent libraries — your sketch is the bridge. No library knows about the others.
// In begin(): pass a lambda that reads the timer state from the GUI
pump.begin(
[]() {
// return true when current time falls inside any timer slot
uint16_t nowMin = rtcHour * 60 + rtcMinute;
for (uint8_t i = 0; i < APA_LCD_MAX_TIMERS; i++) {
if (gui.isTimerEnabled(i) &&
nowMin >= gui.getTimerStart(i) &&
nowMin < gui.getTimerEnd(i)) return true;
}
return false;
},
nullptr,
[]() { return gui.getTimerTotalMinutes(); } // daily target from timer sum
);// Keep the pump running during a shock and for 4 hours after it, to circulate the
// chlorine (a schedule slot ending mid-shock would otherwise stop the pump and
// APADOSE would abort the shock). Uses the externalRequestCb — no new API needed.
// Elapsed-time check, so it stays correct when millis() wraps after ~49 days.
const uint32_t POST_SHOCK_MS = 4UL * 3600UL * 1000UL;
uint32_t postShockEndMs = 0; // 0 = no post-shock window
bool postShockWantsPump() {
if (dose1.isShockActive()) {
postShockEndMs = millis() | 1; // |1: never 0, the "no window" marker
return true;
}
if (postShockEndMs == 0) return false;
if (millis() - postShockEndMs < POST_SHOCK_MS) return true;
postShockEndMs = 0;
return false;
}
pump.begin(scheduleCb, postShockWantsPump);// Show [M] in the LCD corner whenever the pump is in manual mode
pump.setStatusCallback([](const __FlashStringHelper* msg) {
if (pump.getManualMode() != AUTO) gui.setStatusIndicator('M');
else gui.clearStatusIndicator();
// Also forward the status text to a scrolling message area
Serial.println(msg);
});// Order: adc.begin() BEFORE pump.begin() — pressure auto-zeros on first pump stop.
// pressureCb returns -1.0f while APASENSE is uncalibrated — APAPUMP skips
// all pressure logic until a valid reading arrives.
adc.begin(); // zero-cal requires pump off — call first
pump.begin();
pump.enablePressure(
[]() { return adc.getPressure(); }, // -1.0f until calibrated
2.5f // alarm limit = filter's rated pressure (bar)
);
pump.setCurrentCallback([]() { return adc.getCurrent(); }); // amps; silent below 0.5 A
// Bridge: tell APASENSE when pump state changes so it can re-zero on pump stop
pump.setPumpStateCallback([](bool on) { adc.onPumpState(on); });| Sketch | Level | Description |
|---|---|---|
examples/01_minimal/ |
Basic | PCF or GPIO, manual override via Serial, all three constructor options |
examples/02_scheduler/ |
Intermediate | APALCDGUI timer schedule, UVC + AUX followers, alarm → active alert bridge |
examples/03_solar_freeze/ |
Advanced | Solar heater + solar valve, freeze protection, pressure + current safety, filter status, pump stopped on alarm, APADOSE post-shock bridge |
Compiled with the 01_minimal example. Zero errors, zero library warnings on all platforms.
| Platform | Board | RAM used | RAM total | Flash used | Flash total |
|---|---|---|---|---|---|
| Arduino Mega 2560 | ATmega2560 | 564 B | 8 192 B (6.9%) | 11 952 B | 253 952 B (4.7%) |
| Arduino Uno | ATmega328P | 564 B | 2 048 B (27.5%) | 11 186 B | 32 256 B (34.7%) |
| ESP32 DevKit | ESP32 | 22 024 B | 327 680 B (6.7%) | 290 709 B | 1 310 720 B (22.2%) |
| ESP8266 D1 Mini | ESP8266 | 28 852 B | 81 920 B (35.2%) | 274 271 B | 1 044 464 B (26.3%) |
| STM32 Bluepill | STM32F103C8 | 2 628 B | 20 480 B (12.8%) | 26 068 B | 65 536 B (39.8%) |
The Uno row uses 27.5% RAM — that is the library with all Phase 2 features registered in the example. A minimal sketch (no solar, no pressure, no freeze) sits below 20%. ESP32 and ESP8266 totals include the full Arduino framework regardless of use.
APAPUMP reserves 12 bytes starting at APAPUMP_EEPROM_ADDR (default 520).
| Address | Bytes | Field | Saved when |
|---|---|---|---|
| 520 | 2 | Magic 0xA55A |
— validity marker |
| 522 | 1 | Config version | — mismatch resets all fields to defaults |
| 523 | 2 | Daily target (minutes) | setDailyTarget() |
| 525 | 2 | Yesterday's runtime (minutes) | Midnight rollover (once per day) |
| 527 | 2 | Minimum run time (seconds) | setMinRunTime() |
| 529 | 2 | Clean pressure × 100 (bar; 0 = not learned) | automatic first learn, learnCleanPressure(), setCleanPressure() |
| 531 | 1 | Checksum (byte sum of bytes 520–530) | — corruption guard |
_saveEEPROM() writes the full 12-byte struct, but a physical write only occurs when a byte has actually changed:
- AVR (Uno/Mega):
EEPROM.put()callsEEPROM.update()per byte — reads first, writes only if value differs. - ESP32/ESP8266:
EEPROM.put()updates a RAM buffer;EEPROM.commit()compares the buffer to flash before writing — no flash write if content unchanged. - STM32: EEPROM emulation with compare-before-write.
Practical write frequency (worst case on a running system):
| Event | Max frequency | Cycles used at 100 k limit |
|---|---|---|
| Midnight rollover | 1 per day | 100 k days ≈ 273 years |
Clean pressure (first learn, learnCleanPressure()) |
After install / after each backwash | Negligible |
setMinRunTime() from setup() |
0 physical writes if value unchanged | None |
| First boot / corruption recovery | Once | 1 cycle |
Corruption recovery: the checksum is verified on every begin(). If power fails mid-write and data is corrupted, the mismatch is detected on the next boot, factory defaults are loaded, and a clean struct is written.
; platformio.ini — build_flags reach both your sketch and the library's own .cpp
build_flags = -DAPAPUMP_EEPROM_ADDR=532All ranges across the APA library suite — free blocks shown explicitly:
| Range | Bytes | Status | Owner |
|---|---|---|---|
| 0–127 | 128 | free | — |
| 128–177 | 50 | used | APAPHX2_ADS1115 (sensor calibration) |
| 178–188 | 11 | free | — |
| 189–191 | 3 | used | APADOSE global (pool volume, dead-band) |
| 192–291 | 100 | used | APADOSE per-pump config (25 bytes × up to 4 instances) |
| 292–499 | 208 | free | — |
| 500–501 | 2 | used | APALCDGUI brightness |
| 502–508 | 7 | used | APALCDGUI timer slots (default 3 slots) |
| 509–519 | 11 | free | — gap before APAPUMP ¹ |
| 520–531 | 12 | used | APAPUMP |
| 532–581 | 50 | free | — APAPUMP expansion reserve |
| 582–587 | 6 | used | APASENSE (pressure zero) |
| 588– | — | free | — |
¹ When
APA_LCD_MAX_TIMERS=6the timer block extends to 514, leaving a 5-byte gap (515–519) before APAPUMP. This gap is intentional — do not place anything in 515–519 to keep the gap safe regardless of timer configuration.
Dual license — see LICENSE file for full terms.
| Use | License |
|---|---|
| Personal, private, educational, hobby | Free — no charge, no paperwork |
| Commercial (products, services, OEM) | Separate written license required |
Commercial use includes selling or distributing hardware with this software, providing paid pool automation services, or integrating it into any revenue-generating product or system.
To obtain a commercial license: kecup@vazac.eu
APAPUMP — APA Devices · kecup@vazac.eu